Linear Heat Detection

                        NEWSHEET10

TRANSFORMER PROTECTION 

                                    Other Fire Protection & Heat Detection Newsheets

 

                           
                           

The risk of Overheat and / or Fire conditions on Power Transformers and Generator sets  remain high – even where regular maintenance programmes are operated and where shielding , grounding and lightning arrestor devices are installed . With  fire detection or protection ( combined detection + extinguishing  ) systems generally specified or recommended by site operators and plant manufacturers  .
The primary sources of fires vary of course  – depending upon whether the risk is  a transformer or Generator , and includes overheating / ignition of diesel , dirty insulators ,  insulation deterioration which produces arcing and an associated overheat of the insulating oil – causing the tanks to rupture – which in turn produces further arcing and the commencement of a fire . Plus ,  lightning stikes on  transformer units.

The most effective detection of the overheat condition ( pre- combustion ) or the fire itself is by DIGITAL LINEAR HEAT DETECTION .  A combined detector and cable in one which monitors local temperature changes , and is able to operate continuously within adverse environments and areas of  limited access and surveillance . The fixed temperature ( non length dependant ) line based system can be installed either directly onto the device it is protecting via plastic cable ties and mounts , or to  very local extinguishing pipework ( where installed ) , and should be routed around all sides of the transformer or generator at BOTH top and bottom levels in order to maximise protection and ensure fastest response times .

Linear Heat sensor cables supplied and / or manufactured by  PROLINE PROTECTION SYSTEMS LTD ,are colour coded for alarm temperature verification,  flame retardant, corrosion and abrasion resistant (as standard),  and offer U.L. listing or F.M. approvals as a minimum . When used in conjunction with an optional dedicated interface unit , they can also provide “alarm point location “ facilities  ( the identification by integral meter of the exact alarm point along a zone run of sensor cable – with any interconnecting cabling calibrated out ) - Of particular advantage on pre-combustion detection situations where no visible flame exists ! 


For more information – contact www.lineardetection.com or email – proline@linedetect.com
                    

 

   

   
  
  


 

 

About Contact Send us an Enquiry Linear Heat Detection General Linear Heat Detection Products Linear Heat - Fixings/Supports Linear Heat - Junction Boxes Linear Heat Detection Applications Linear Detection - Design Newsheets Consultant Specification FAQ's Product Approvals Speciality Cables Beam Detectors Flame Detectors Aspirated Smoke Detector Moisture Detection Stop Press Terms and Conditions Payment Terms